Sc Apc Ua
Drop cables yog cov cables uas khiav los ntawm qhov chaw xa khoom lossis cable mus rau tus neeg siv khoom / neeg siv.
Fiber patch cord, feem ntau hu ua fiber ntau thaj cable, fiber ntau jumper, los yog fiber ntau patch lead, yog qhov ntev ntawm fiber ntau cable uas tau txiav nrog fiber ntau optic connectors ntawm txhua qhov kawg. Cov khoom sib txuas tso cai rau fiber ntau optic thaj qaum txuas mus rau qhov hloov kho qhov muag lossis lwm yam kev sib txuas lus / khoos phis tawj.
Hauj lwm lawm
Kev tsis
peb lub tuam txhab
Environmental yam ntxwv
- Kev thauj mus los / cia kub: -20℃rau +60 degree
Kev xa khoom ntev
- Standard reel ntev: 5m, 10m, 20m, 35m, 45m, 50m, 75m, 100m, 150m, 200m, 300m;
- Lwm qhov ntev kuj muaj.
Peb cov kev pabcuam
1. 24-teev ib - ntawm- ib qho kev pabcuam online kom ntseeg tau tias muaj kev txhawb nqa zoo.
2. Kev xav zoo rau cov neeg txais tos los ntawm lub tsev so booking mus rau lub Hoobkas.
3. Ceev faj heev thoob plaws hauv cov txheej txheem los ntawm kev txiav txim kom paub meej txog cov khoom xa tuaj.
tus kheej hom
Ntim thiab nkoj
Tswv yim
## I. Cov Ntsiab Lus Txhais: Lub npe tawg
### 1. SC Connector
SC (Standard Connector): Square thawb- rub fiber ntau optic connector, 2.5mm ceramic ferrule, cuab yeej- pub dawb tso thiab tshem tawm, feem ntau yog siv hauv chav tsev thiab PON broadband. Distinguished los ntawm lub plhaub xim:
- **SC/UPC**: Blue plhaub, 0℃me ntsis convex nto polishing
- **SC/APC**: Ntsuab plhaub, 8℃bevel polishing
### 2. Qhov sib txawv ntawm cov tub ntxhais hauv UPC/APC Endface Polishing
Cov lus sib piv: SC / UPC vs SC / APC Fiber Connectors

### 3. Dab tsi yog SC/UPC -SC/APC thaj qaum?
**Ib ib qho -hom hybrid fiber optic thaj qaum nrog xiav SC UPC txuas ntawm ib kawg thiab ntsuab SC APC txuas rau lwm qhov.** Nws yog tsim tshwj xeeb rau kev sib txuas ntawm tus ntoo khaub lig-qhov kev sib txuas uas ib qho kawg yog UPC thiab lwm qhov yog APC, tshem tawm qhov xav tau ntawm cov khoom siv txuas ntxiv thiab txo qis cov ntsiab lus tsis zoo.
## II. Qauv thiab Specifications
1. **Fiber Optic Type**: Tsuas yog ** ib zaug-mode 9/125μm OS2 (G.652D/G.657A1/A2)**, multimode yam tsis muaj APC txheej txheem, tsis muaj multimode SC/UPC-SC/APC thaj qaum.
2. **Cable Type**
- Ib leeg-core Simplex: 1 fiber, unidirectional kis tau tus mob;
- Duplex: 2 fibers, ib qho kev xa tawm thiab ib qho tau txais, kev sib txuas lus bidirectional;
3. **Ob Sheath**
- Standard PVC: daj sab hauv tsev qauv thaj qaum;
- LSZH Tsawg Smoke Halogen-Dawb: Rau cov chav tsev computer thiab cov xwm txheej tiv thaiv hluav taws hauv tsev;
- Xaiv 0.9mm nruj- ntim, 2.0/3.0mm puag ncig thaj qaum;
4. **Common Lengths**: 0.5m/1m/2m/3m/5m/10m/15m/20m, thiab lwm yam, customizable.
## III. Qhov tseem ceeb Optical Performance (Industry Standard)
1. **Insertion Loss IL**: Ib leeg- xaus Less dua los yog sib npaug rau 0.3dB, tag nrho thaj qaum Tsawg dua los yog sib npaug rau 0.5dB;
2. ** Rov Los Loss RL **: UPC kawg Ntau dua lossis sib npaug rau -50dB, APC kawg Ntau dua lossis sib npaug rau -60dB;
3. Ntxig / tshem tawm lub neej: Ntau dua lossis sib npaug rau 1000 lub voj voog ntawm kev ua haujlwm ruaj khov;
4. Ua haujlwm kub: -40℃~ +85℃.
## IV. Core Use Cases (Vim li cas thiaj siv Qhov Hybrid Patch Cord?)
Qhov tsuas yog qhov tseem ceeb siv rooj plaub rau cov hlua txuas no yog ** tsis sib haum xeeb ntawm cov khoom siv tshiab thiab qub cuam tshuam ** hauv cov chaw zov me nyuam / broadband networks:
1. ** FTTH PON Broadband Data Centers **
OLT cov khoom siv chaw nres nkoj feem ntau yog ** SC / APC (ntsuab) **, thaum qhov chaw nres nkoj kho qhov muag ntawm cov ntaub ntawv chaw nyob sab hauv network thaj vaj huam sib luag thiab cov keyboards yog ** SC / UPC (xiav) **. Siv cov hlua khi no los txuas ncaj qha rau lub splitter thiab qhov hloov pauv hloov "patch qaum + flange adapter," txo qhov poob.
2. **Cable TV CATV Fiber-Coaxial Convergence Network** Lub pem hauv ntej-kawg RF optical transmitter yog APC (Anti-Reflection Interference Analog Television Signal), thiab cov ntaub ntawv hloov pauv yog UPC, ua kom cable-raws li kev sib kis thiab kev sib tshuam rau ob qho tib si cable thiab broadband.
3. **Txoj Kev Txhim Kho Cov Khoom Siv Hluav Taws Xob** UPC thaj vaj huam sib luag nyob rau hauv cov cuab yeej qub chav tuaj yeem hloov kho nrog XGS tshiab-PON/50G-PON APC cov cuab yeej yam tsis tau hloov tag nrho cov xaim hluav taws xob, muab cov nqi qis - kev hloov kho kom haum tau zoo.
4. **Hybrid Transmission Laboratory thiab Optical Testing Instruments** Instrument ports include UPC digital ports and APC RF test ports for cross-endpoint optical path testing.
## V. Tseem ceeb siv txwv thiab ceev faj
1. ** Tsis txhob yuam kev ncaj nraim ntawm UPC thiab APC Flanges ** Kev yuam kev sib txuas ntawm UPC thiab APC flanges nrog 8℃bevel thiab 0℃tiaj tus nto yuav tsim qhov sib txawv ntawm huab cua loj: qhov poob yuav nce 10 ~ 15dB, ua rau cov pob ntawv poob hnyav, zoo li qub hauv TV, thiab kev puas tsuaj rau lub sijhawm ntev {{5}.
→ ** Ib qho ua ntej- ua SC/UPC-SC/APC hybrid thaj qaum yuav tsum tau siv rau kev hloov pauv; zoo tib yam flange adapters tsis tau.**
2. **Txhais qhov polarity ntawm ob qhov kawg; tsis txhob thim rov los yog sib tov.**
APC kawg yuav tsum txuas nrog PON OLT lossis CATV RF khoom; UPC kawg yuav tsum tau txuas nrog lub hloov pauv lossis cov ntaub ntawv thaj vaj huam sib luag.
Yog tias APC txuas nrog qhov hloov pauv zoo tib yam, qhov rov qab poob ntau dhau tsis muaj qhov cuam tshuam tsis zoo, tab sis tus nqi siab dua; Txuas UPC rau PON optical modem yuav ua rau kev sib txuas hauv network thiab kev sau npe tsis ua haujlwm vim muaj kev xav.
3. **Lub ntsej muag kawg yuav tsum huv.**
Lub beveled nto ntawm APC yog ntau yooj yim rau plua plav. Ntxuav nws nrog fiber ntau optic tu daim ntawv thiab dej cawv anhydrous ua ntej ntsaws thiab tshem tawm kom tsis txhob muaj kev cuam tshuam kev cuam tshuam.
4. **Kev sib txawv xim ceev.**
Blue connector=UPC (digital equipment side), ntsuab connector=APC (PON/broadcast equipment side) kom tsis txhob muaj kev ntxhov siab thaum lub sijhawm teeb tsa.
## VI. Kev sib piv nrog Tib -Endface Patch Cords
1. SC/UPC-SC/UPC: Pure digital intranet, data center, tsis muaj PON/CATV scenarios;
2. SC/APC-SC/APC: Puv PON, puv - txuas cable TV;
3. SC/UPC-SC/APC: **Dedicated hloov pauv thaj qaum rau tus ntoo khaub lig-endface hybrid systems**, feem ntau siv txoj kev hloov cable rau cov ntaub ntawv chaw hloov khoom dua tshiab.
## VII. Cov lus pom zoo xaiv
1. Ordinary indoor data center: Yellow PVC 3.0mm ib leeg -core/dual-core;
2. Cov tsev ua haujlwm, chav tswj hluav taws kub: Xaiv LSZH qis- pa taws halogen-dawb sheath;
3. Ntev-nruab deb nkhaus cabling: Xaiv G.657 khoov-insensitive ib leeg- hom fiber ntau;
4. Ua ntej lub Hoobkas ua ntej -prefabricated thaj qaum. Ntawm -site phau ntawv kev sib tsoo ntawm qhov sib xyaw ua ke yog txwv tsis pub vim qhov tsis tuaj yeem tswj tau.
Cim npe nrov: sc apc upc, Tuam Tshoj sc apc upc manufacturers, lwm tus neeg, Hoobkas
Cov yam ntxwv
| Cable Part | |
| Fiber suav | 1~4 |
| Fiber hom | G657A1 los yog A2 |
| Strength Member Material | FRP los yog steel hlau |
| Dielectric zog Cov tswv cuab loj | 2 x 0.5 hli / 2 x 0.4 hli |
| Cov khoom siv tub txib | Hlau hlau |
| Messenger loj | 1.0 hli / 7 * 0.33mm |
| Nominal Qhov Loj (± 0.3) | 2.0mm x 5.0 hli |
| Outer Jacket Khoom | LSZH |
| Tension Strength (Short-Term / Long-Term) | 300N/600N |
| Crush Resistance (Short-Term / Long-Term) |
1000 N / 100 hli 2200 N / 100 hli |
| Yam tsawg kawg nkaus Khoov Radius (Static / Dynamic) | 20 x OD / 40 x OD |
| Connectors ib feem | |
| Hom Connector | SC/UPC, SC/APC |
| Insertion Loss | Tsawg dua lossis sib npaug li 0.25dB |
| Rov Los Loss (Rau Ib Hom) | UPC Ntau dua lossis sib npaug rau 50dB, APC Ntau dua lossis sib npaug rau 60dB |
| Rov ua dua | ± 0.1dB |
* Tag nrho saum toj no lub cable loj tuaj yeem hloov kho.
Tug
FTTHTom ntej
kab ftth 1 coreXa kev nug